Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2018, 09:28 AM
  • 02 1803_02 1802_03102018_022955.mp4

Date
10/03/2018
W/O
729701
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00292
PipeID
P04148
Time
2:28 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6125
Sewer Name
02 MONTEREY PARK RELIEF TRUNK
City
EAST LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_729701_TV02108_OCT2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1802
Downstream MH
02 1803
Dir. of Survey
Upstream
Length Surveyed
127.8 ft.
Total Length
127.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1802 to 02 1803
MH: 02 1802MH: 02 1803upstream0 ft. MSA - Survey Abandoned - REACHED POINT WHERE FLIPPED OVER5.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"17.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"44.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"62.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"97.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"118.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.8 ft. MGO - General Observation - LINED PIPE127.8 ft. MWM - Water Mark, 5 %of cross sectional area127.8 ft. MWL - Water Level, 5 %of cross sectional area127.8 ft. AMH - Downstream Manhole, Survey Begins - 02 1802127.8 ft. MGO - Reversal Inspection

Observations (13)

DistanceCodeObservation
29.9TF
41.7TF
0MWM
65.4TF
110.5TF
9.1TF
0MWL
4MGOLINED PIPE
83.3TF
127.8MSAREACHED POINT WHERE FLIPPED OVER
121.9TF
0AMH02 1802
0MGO

Properties (6)

additional_info
SC364845
custom_field_two
3
customer
LACSD
datetime
2018-10-03T02:28:48-07:00
documentation
PROPIPE
is_lateral_inspection
false