Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 1, 2018, 10:46 AM
  • 05 1588_05 1587_1112018_035145.mp4

Date
11/01/2018
W/O
0736672
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00485
PipeID
P06812
Time
3:46 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1036
Sewer Name
05 MARICOPA STREET TRUNK
City
T0RRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
26
Purpose
Capital Improvement Program Assesment
Project
20181026MDM_MARICOPA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 1588
Downstream MH
05 1587
Dir. of Survey
Downstream
Length Surveyed
81.9 ft.
Total Length
81.9 ft.
Structural Index
2
Structural Quick
362A
Structural Rating
42
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
48
Pipe schematic from manhole 05 1588 to 05 1587
MH: 05 1588MH: 05 1587downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 3:40AM0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: NO3.8 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT8.6 ft. DSZ - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO - SLUDGE14.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL14.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE18.9 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H18.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H24.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL29.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H34.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H34.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H39.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL44.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL44.6 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H44.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H55.1 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SL60.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H60.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H70.2 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H75.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL81.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish81.9 ft. AMH - Downstream Manhole, Survey Ends - 3:55AM

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (27)

DistanceCodeObservation
14.2FCSL
2.3DAGS
55.1FCSL
44.6FLSL
0MWL
34.7FLH
29.3FCH
44.6FCH
14.2FCHAIRLINE
18.9FCH
24.5FCSL
60.1FLH
0MGOConn. @ Mh, 3 O' Clock. Active
39.6FLSL
75.4FCSL
0AMH3:40AM
60.1FCH
8.6DSZSLUDGE
34.7FLH
81.9AMH3:55AM
0MWM
2DAGS
44.6FLH
70.2FCH
3.8FCSLIGHT
18.9FCH
81.4DAGS

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-11-01T03:46:46-07:00
documentation
MARTIN,REVELES
is_lateral_inspection
false