Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2018, 10:44 AM
  • 05 1575_05 1574_10302018_034859.mp4

Date
10/30/2018
W/O
0736672
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00485
PipeID
P06799
Time
3:44 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1034
Sewer Name
05 MARICOPA STREET TRUNK
City
T0RRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
26
Purpose
Capital Improvement Program Assesment
Project
20181026MDM_MARICOPA_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 1575
Downstream MH
05 1574
Dir. of Survey
Downstream
Length Surveyed
258.9 ft.
Total Length
258.9 ft.
Structural Index
2
Structural Quick
3229
Structural Rating
24
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
26
Pipe schematic from manhole 05 1575 to 05 1574
MH: 05 1575MH: 05 1574downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: NO - INSIDE MH4.5 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT8.9 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL16.6 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE20.7 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H24.9 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H29.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL29.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL32.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS32.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS32.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS32.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS116.7 ft. MGO - General Observation - 18" VCP258.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - 10% SLIGHT AT JOINTS258.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active258.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - 10% HAIRLINE AT JOINTS258.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - 30% HAIRLINE AT JOINTS258.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped258.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - 30% SLIGHT AT JOINTS258.9 ft. AMH - Downstream Manhole, Survey Ends - 4:10AM

Observation photos (1)

  • General Observation - 18" VCP

    116.7 ft. - General Observation - 18" VCP

Observations (25)

DistanceCodeObservation
0MGOConn. @ Mh, 3 O' Clock. Active
258.3FL10% SLIGHT AT JOINTS
8.9FCSL
258.3MGOConn. @ Mh, 3 O' Clock. Active
16.6FCHAIRLINE
32.8FCSLIGHT AT JOINTS
20.7FCH
258.3FL10% HAIRLINE AT JOINTS
258.3FC30% HAIRLINE AT JOINTS
32.8FLSLIGHT AT JOINTS
32.8FLHAIRLINE AT JOINTS
258.3MGOConn. @ Mh, 9 O' Clock. Capped
0MWM
32.8FCHAIRLINE AT JOINTS
0MWL
258.3FC30% SLIGHT AT JOINTS
24.9FCH
0MGOConn. @ Mh, 9 O' Clock. Capped
4.5FCSLIGHT
29.3FCSL
29.3FCSL
116.7MGO18" VCP
1DAGSINSIDE MH
258.9AMH4:10AM
0AMH3:50AM

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2018-10-30T03:44:46-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false