Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 7, 2018, 12:13 PM
  • Section#1_-_C 0662__272018__G6951.mp4

Date
02/07/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01115
PipeID
P24010
Time
4:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6951
Sewer Name
29 CALIFORNIA AVENUE SEWER
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20180207MDM_CALIFORNIA_AVENUE_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
C 0662
Downstream MH
-
Dir. of Survey
Upstream
Length Surveyed
114.2 ft.
Total Length
114.2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole C 0662 to -
MH: C 0662MH: -upstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:30AM1.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN1.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN4.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB8 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - OPEN8.5 ft. FC - Fracture Circumferential, from 07 to 02 o'clock, within 8 inches of joint: YES - SLIGHT24.6 ft. MGO - General Observation - 8" VCP74.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB77.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - STUB114.2 ft. MWM - Water Mark, 30 %of cross sectional area114.2 ft. AMH - Downstream Manhole, Survey Begins - 4:10AM114.2 ft. MWL - Water Level, 0 %of cross sectional area

Observation photos (1)

  • General Observation - 8" VCP

    89.6 ft. - General Observation - 8" VCP

Observations (12)

DistanceCodeObservation
114.2AMH4:30AM
39.4TFCSTUB
110TFCSTUB
0MWM
105.7FCSLIGHT
112.7TFOPEN
36.6TFCSTUB
106.2TBOPEN
0AMH4:10AM
89.6MGO8" VCP
0MWL
112.7TFOPEN

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2018-02-07T04:13:23-08:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false