Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 6, 2018, 08:56 AM
  • Section#1_29 0231_29 0230__262018__,. G6949.mp4

Date
02/06/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01020
PipeID
P24133
Time
12:56 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
,. G6949
Sewer Name
29 WALNUT AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20180206MDM_WALNUT_AVENUE_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0231
Downstream MH
29 0230
Dir. of Survey
Downstream
Length Surveyed
340.4 ft.
Total Length
340.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 29 0231 to 29 0230
MH: 29 0231MH: 29 0230downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 0 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM8 ft. MGO - General Observation - 8" VCP77 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB79.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - STUB179.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN181.6 ft. MWL - Water Level, 1 %of cross sectional area181.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE202.6 ft. MGO - General Observation - 8" VCP269.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE340.4 ft. AMH - Downstream Manhole, Survey Ends - 1:50AM

Observation photos (2)

  • General Observation - 8" VCP

    8 ft. - General Observation - 8" VCP

  • General Observation - 8" VCP

    202.6 ft. - General Observation - 8" VCP

Observations (12)

DistanceCodeObservation
202.6MGO8" VCP
181.6MWL
181.6TFACTIVE
8MGO8" VCP
77TFCSTUB
0MWM
79.5TFCSTUB
269.9FLHAIRLINE
340.4AMH1:50AM
179.1TFOPEN
0MWL
0AMH1:20AM

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2018-02-06T00:56:10-08:00
documentation
MARTIN,MANANES
is_lateral_inspection
false