Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 5, 2018, 08:56 AM
  • Section#3_29 0277_29 0276__252018__G6947.mp4

Date
02/05/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00543
PipeID
P24185
Time
12:56 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6947
Sewer Name
29 ORANGE AVENUE TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
20180205MDM_ORANGE_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0277
Downstream MH
29 0276
Dir. of Survey
Downstream
Length Surveyed
321.8 ft.
Total Length
321.8 ft.
Structural Index
3
Structural Quick
3C28
Structural Rating
70
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
70
Pipe schematic from manhole 29 0277 to 29 0276
MH: 29 0277MH: 29 0276downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:20AM0 ft. MWM - Water Mark, 10 %of cross sectional area9.5 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE10.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - STUB15.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H15.2 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H27.3 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H27.3 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H27.3 ft. MGO - General Observation - 8" VCP33.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H45.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H46.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H51.1 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H60.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H61.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN74.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H74.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SLIGHT80.9 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT97 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6" - STUB132.7 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN140.3 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H141.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 6" - STUB148.8 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H150.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6" - STUB184.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL198 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6" - STUB207.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H215.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN222.8 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H222.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H232.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - SL245.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6" - STUB254 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN258.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H273.4 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H285.5 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H286.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6" - STUB309.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H309.2 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H315.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - SL321.5 ft. MGO - General Observation - MH CONN 9:00 ACTIVE321.8 ft. AMH - Downstream Manhole, Survey Ends - 2:55AM

Observation photos (1)

  • General Observation - 8" VCP

    27.3 ft. - General Observation - 8" VCP

Observations (43)

DistanceCodeObservation
222.8FCH
184.8FLSL
285.5FCH
215.6TFOPEN
27.3FLH
60.1FLH
150.2TFCSTUB
140.3FCH
27.3FLH
45.4FLH
198TFCSTUB
321.8AMH2:55AM
245.1TFCSTUB
207.7FLH
51.1FCH
321.5MGOMH CONN 9:00 ACTIVE
61.2TFOPEN
74.9FLH
15.2FLH
232.2FLSL
10.6TFCSTUB
286.6TFCSTUB
80.9FCSLIGHT
148.8FCH
0MWL
141.3TFCSTUB
254TFOPEN
273.4FLH
309.2FLH
97TFCSTUB
33.5FLH
222.8FLH
46.3FLH
0AMH2:20AM
315.2FLSL
0MWM
27.3MGO8" VCP
9.5FCHAIRLINE
74.9FLSLIGHT
15.2FCH
132.7TFOPEN
258.2FLH
309.2FLH

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-02-05T00:56:20-08:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false