Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 18, 2018, 12:05 PM
  • Section#5_02 1766_02 1765__9182018__I0070.mp4

Date
09/18/2018
W/O
0730104
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00271
PipeID
P04114
Time
5:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Heavy Cleaning
Media Label
I0070
Sewer Name
02 INDIANA STREET TRUNK
City
LOS ANGLES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11A
Purpose
Maintenance Related
Project
20180918MDM_INDIANA_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
7.489999771118164 in.
Upstream MH
02 1767
Downstream MH
02 1766
Dir. of Survey
Downstream
Length Surveyed
279.2 ft.
Total Length
279.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole 02 1767 to 02 1766
MH: 02 1767MH: 02 1766downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:10AM0 ft. MWL - Water Level, 5 %of cross sectional area8 ft. MGO - General Observation - 7.49" NRCP-CIPP15.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN46.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN-NO GREASE71.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN-NO GREASE135.4 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - ACTIVE-25% GREASE TOP AREA148.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN217 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN- 80% GREASE232.3 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE-95% GREASE279.2 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (4)

  • General Observation - 7.49" NRCP-CIPP

    8 ft. - General Observation - 7.49" NRCP-CIPP

  • Tap Break-In Defective, at 02 o'clock, -,  , within 8 inches of joint: NO, 6" - ACTIVE-25% GREASE TOP AREA

    135.4 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - ACTIVE-25% GREASE TOP AREA

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN- 80% GREASE

    217 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN- 80% GREASE

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE-95% GREASE

    232.3 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE-95% GREASE

Observations (12)

DistanceCodeObservation
71.9TBOPEN-NO GREASE
0MWM
217TFDOPEN- 80% GREASE
0AMH5:10AM
15.7TBOPEN
279.2AMH5:40AM
232.3TFDACTIVE-95% GREASE
0MWL
135.4TBDACTIVE-25% GREASE TOP AREA
148.3TBOPEN
8MGO7.49" NRCP-CIPP
46.5TBOPEN-NO GREASE

Properties (4)

customer
LACSD
datetime
2018-09-18T05:05:13-07:00
documentation
MARTIN,REVELES,OLIVER 111,BRAR
is_lateral_inspection
false