- Date
- 09/18/2018
- W/O
- 0730104
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00271
- PipeID
- P04114
- Time
- 5:05 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Heavy Cleaning
- Media Label
- I0070
- Sewer Name
- 02 INDIANA STREET TRUNK
- City
- LOS ANGLES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 11A
- Purpose
- Maintenance Related
- Project
- 20180918MDM_INDIANA_STREET_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 7.489999771118164 in.
- Upstream MH
- 02 1767
- Downstream MH
- 02 1766
- Dir. of Survey
- Downstream
- Length Surveyed
- 279.2 ft.
- Total Length
- 279.2 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 3122
- O&M Rating
- 7
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 02 1767 to 02 1766 Observation photos (4)

8 ft. - General Observation - 7.49" NRCP-CIPP

135.4 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - ACTIVE-25% GREASE TOP AREA

217 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN- 80% GREASE

232.3 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE-95% GREASE