- Date
- 05/02/2018
- W/O
- 695981
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00225
- PipeID
- P02039
- Time
- 11:06 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5553
- Sewer Name
- 01 WILCOX AVENUE TRUNK
- City
- BELL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- WO_695981_TV01257_APR2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 01 1185
- Downstream MH
- 01 1184
- Dir. of Survey
- Downstream
- Length Surveyed
- 394.5 ft.
- Total Length
- 394.5 ft.
- Structural Index
- 3
- Structural Quick
- 3^00
- Structural Rating
- 468
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 468
Pipe schematic from manhole 01 1185 to 01 1184 Observation photos (4)

2.3 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

3.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

50.6 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES

94.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start