Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 16, 2018, 07:17 PM
  • 19 0111_19 0110_5162018_122233.mp4

Date
05/16/2018
W/O
0700687
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00722
PipeID
P15300
Time
12:17 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7712
Sewer Name
19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
05
Purpose
Routine Assessment
Project
20180516DF_EAST_ARTESIA_TRUNK_SECTS_1_2_3_5
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
19 0111
Downstream MH
19 0110
Dir. of Survey
Downstream
Length Surveyed
111 ft.
Total Length
111 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 19 0111 to 19 0110
MH: 19 0111MH: 19 0110downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:20 PM0.1 ft. MWL - Water Level, 60 %of cross sectional area0.1 ft. MWM - Water Mark, 65 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start8 ft. MGP - General Photograph15.4 ft. MGP - General Photograph42.2 ft. MGP - General Photograph58.8 ft. MGP - General Photograph71.3 ft. MGP - General Photograph84.4 ft. MGP - General Photograph94.6 ft. MGP - General Photograph105 ft. MGP - General Photograph109.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish109.5 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish110 ft. MGO - General Observation - ROACHES @ MH111 ft. AMH - Downstream Manhole, Survey Ends - 1:06 PM

Observation photos (12)

  • Water Level, 60 %of cross sectional area

    0.1 ft. - Water Level, 60 %of cross sectional area

  • Water Mark, 65 %of cross sectional area

    0.1 ft. - Water Mark, 65 %of cross sectional area

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 15 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • General Photograph

    8 ft. - General Photograph

  • General Photograph

    15.4 ft. - General Photograph

  • General Photograph

    42.2 ft. - General Photograph

  • General Photograph

    58.8 ft. - General Photograph

  • General Photograph

    71.3 ft. - General Photograph

  • General Photograph

    84.4 ft. - General Photograph

  • General Photograph

    94.6 ft. - General Photograph

  • General Photograph

    105 ft. - General Photograph

Observations (17)

DistanceCodeObservation
71.3MGP
109.5DAGS
0.1MWL
110MGOROACHES @ MH
84.4MGP
42.2MGP
0AMH12:20 PM
105MGP
94.6MGP
109.4SSS
58.8MGP
2SSS
2DAGS
8MGP
111AMH1:06 PM
0.1MWM
15.4MGP

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-05-16T12:17:44-07:00
documentation
FRANKLIN, VENDRYES
is_lateral_inspection
false