Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2018, 06:10 AM
  • J 0321A_J 0321_31012018_224605.mp4

Date
01/31/2018
W/O
684879
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00059
PipeID
P11565
Time
10:10 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5429
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
PALOS VERDES ESTATES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
12
Purpose
Routine Assessment
Project
WO_684879_TV05330_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
J 0321A
Downstream MH
J 0321
Dir. of Survey
Downstream
Length Surveyed
281.4 ft.
Total Length
281.4 ft.
Structural Index
3
Structural Quick
3E21
Structural Rating
91
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
93
Pipe schematic from manhole J 0321A to J 0321
MH: J 0321AMH: J 0321downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 8 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 10 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - J 0321A16.2 ft. CM - Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES20.7 ft. CM - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES51.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES71.5 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES71.7 ft. CC - Crack Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES76.9 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES88 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES127.1 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES137.6 ft. CC - Crack Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES157.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start240.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"281.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish281.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK281.4 ft. AMH - Downstream Manhole, Survey Ends - J 0321

Observation photos (9)

  • Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

    16.2 ft. - Crack Multiple, from 08 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    20.7 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    51.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES

    71.7 ft. - Crack Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    76.9 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    88 ft. - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

    127.1 ft. - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES

    137.6 ft. - Crack Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    157.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
71.7CC
157.2CM
281.3CM
20.7CM
0MWM
240.3TF
0MGOCONNECTION AT MH 8 O'CLOCK
76.9CL
51.2CM
0MWL
88CM
71.5RFJ
0MGOCONNECTION AT MH 10 O'CLOCK
281.4MGOCONNECTION AT MH 9 O'CLOCK
281.4AMHJ 0321
127.1RFJ
137.6CC
0AMHJ 0321A
16.2CM

Properties (6)

additional_info
SC347064
custom_field_two
3
customer
LACSD
datetime
2018-01-31T22:10:59-08:00
documentation
PROPIPE
is_lateral_inspection
false