H 0887_H 0616_2152018_011553.mp4
2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONRETE
2 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
52.9 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG VERY SPORATIC
99.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
179.4 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
185.5 ft. - Deposits Settled Other, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - SLUDGE
313.5 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
317.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
317.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
327.7 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Start - LONG REBAR
327.7 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
357.8 ft. - Surface Reinforcement Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR
357.9 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SEVERE AGG & CORRODED PIPE
357.9 ft. - Surface Aggregate Missing, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
365.5 ft. - Surface Reinforcement Corroded, from 07 to 05 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR
365.5 ft. - Surface Reinforcement Corroded, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR
390.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
390.5 ft. - Surface Reinforcement Corroded, from 09 to 01 o'clock, within 8 inches of joint: NO - MISSING REBAR
390.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
392.8 ft. - Upstream Manhole, Survey Ends - 2:50AM STOPLOG IN PLACE
| Distance | Code | Observation |
|---|---|---|
| 52.9 | SAP | SEVERE AGG SPORATIC |
| 327.7 | SRV | LONG REBAR |
| 365.5 | MGO | ZOOM 27' |
| 99.4 | SSS | BLISTERING CONCRETE |
| 357.9 | DSZ | SEVERE AGG & CORRODED PIPE |
| 392.5 | SAM | SEVERE AGG |
| 65.6 | TFC | Capped |
| 390.5 | SRC | BROKEN MISSING REBAR |
| 365.5 | SSS | BLISTERING PEELING CONCRETE |
| 392.8 | AMH | 2:50AM STOPLOG IN PLACE |
| 365.5 | SAP | SEVERE AGG |
| 317.5 | SRV | CIRCUM REBAR |
| 40.2 | TFC | Capped |
| 0 | MWM | — |
| 285 | TFC | Capped |
| 313.5 | SAP | SEVERE AGG |
| 185.5 | DSZ | SLUDGE |
| 0 | AMH | 1:15AM |
| 313.5 | SAV | SEVERE AGG SPORATIC |
| 346.6 | SRV | CIRCUM REBAR |
| 2 | SSS | BLISTERING PEELING CONRETE |
| 0 | MWL | LOW FLOW UPSTREAM STOPLOG |
| 357.9 | SAM | SEVERE AGG |
| 2 | SAP | SEVERE AGG SPORATIC |
| 365.5 | MGO | 15% DEBRIE STOPPED CAMERA |
| 137.3 | TFC | Capped |
| 392.5 | DSZ | SEVERE AGG & CORRODED PIPE |
| 390.5 | SRC | MISSING REBAR |
| 306.3 | TFC | Capped |
| 365.5 | SRV | LONG CIRCUM REBAR |
| 365.5 | SRC | LONG & CIRCUM REBAR |
| 257.3 | TFC | Capped |
| 233.4 | TFC | Capped |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 179.4 | SAV | SEVERE AGG SPORATIC |
| 332.2 | TF | Open |
| 52.9 | SAV | SEVERE AGG VERY SPORATIC |
| 365.5 | SRC | LONG & CIRCUM REBAR |
| 357.8 | SRV | LONG & CIRCUM REBAR |
| 209.9 | TFC | Capped |
| 346.6 | SRV | LONG REBAR |
| 8 | TFC | Capped |
| 392.5 | SRC | LONG & CIRCUM REBAR |
| 327.7 | SRV | CIRCUM REBAR |
| 317.5 | SRV | CIRCUM REBAR |
| 365.5 | SSS | BLISTERING PEELING CONCRETE |
| 185.5 | TFC | Capped |
| 113.2 | TFC | Capped |
| 390.5 | SRC | BROKEN MISSING REBAR |
| 161.9 | TFC | Capped |
| 355 | TFC | Capped |