Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 12, 2018, 09:55 AM
  • Section#10_J 0207_J 0200__2122018__G6958.mp4

Date
02/12/2018
W/O
0688894
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11451
Time
1:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6958
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
48
Purpose
Capital Improvement Program Assesment
Project
20180210MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0207
Downstream MH
J 0200
Dir. of Survey
Downstream
Length Surveyed
49.7 ft.
Total Length
49.7 ft.
Structural Index
2
Structural Quick
2A00
Structural Rating
20
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
20
Pipe schematic from manhole J 0207 to J 0200
MH: J 0207MH: J 0200downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. MGO - General Observation - MAG COAT 20% START 8:00 TO 4:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE15.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE49.2 ft. MGO - General Observation - MH CONN 3:00 STOPLOG IN PLACE -OPEN49.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE49.2 ft. MGO - General Observation - MAG COAT 20% FINISH49.7 ft. AMH - Downstream Manhole, Survey Ends - 4:00AM

Observation photos (3)

  • General Observation - MAG COAT 20% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 20% START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    15.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

Observations (11)

DistanceCodeObservation
49.7AMH4:00AM
49.2MGOMH CONN 3:00 STOPLOG IN PLACE -OPEN
49.2SSSBLISTERING PEELING CONCRETE
0AMH3:50AM
2MGOMAG COAT 20% START 8:00 TO 4:00
0MWM
49.2MGOMAG COAT 20% FINISH
0MGOMH CONN 9:00 ACTIVE
2SSSBLISTERING PEELING CONCRETE
15.4SSSBLISTERING PEELING CONCRETE
0MWL

Properties (6)

custom_field_three
BLISTERING PEELING CONCRETE
custom_field_two
3
customer
LACSD
datetime
2018-02-12T01:55:16-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection