- Date
- 06/29/2018
- W/O
- 0712093
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00733
- PipeID
- P15237
- Time
- 12:35 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0913
- Sewer Name
- 19 219TH STREET TRUNK
- City
- HAWAIIAN GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 06
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180629SHO_219TH_STREET_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 19 0267
- Downstream MH
- 19 0266
- Dir. of Survey
- Downstream
- Length Surveyed
- 272.7 ft.
- Total Length
- 272.7 ft.
- Structural Index
- 3
- Structural Quick
- 5141
- Structural Rating
- 16
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 20
Pipe schematic from manhole 19 0267 to 19 0266 Observation photos (5)

31 ft. - Surface Spalling, at 12 o'clock, within 8 inches of joint: YES

42.7 ft. - Surface Spalling, at 12 o'clock, within 8 inches of joint: YES

193.7 ft. - Broken, from 02 to 05 o'clock, within 8 inches of joint: YES

238.4 ft. - Fracture Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

262.7 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES