Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 5, 2018, 08:55 AM
  • 03 0565_03 0564_752018_020205.mp4

Date
07/05/2018
W/O
0711839
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00367
PipeID
P05015
Time
1:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0923
Sewer Name
03 LOS COYOTES DIAGONAL RELIEF TRUNK
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
09
Purpose
Routine Assessment
Project
20180629MDM_LOS_COYOTES_DIAGONAL_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
03 0565
Downstream MH
03 0564
Dir. of Survey
Downstream
Length Surveyed
398.7 ft.
Total Length
398.7 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 03 0565 to 03 0564
MH: 03 0565MH: 03 0564downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWL - Water Level, 10 %of cross sectional area5 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - HAIRLINE8.4 ft. MGO - General Observation - 18" VCP376.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - HAIRLNE398.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active398.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN398.7 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observation photos (1)

  • General Observation - 18" VCP

    8.4 ft. - General Observation - 18" VCP

Observations (9)

DistanceCodeObservation
5FLHAIRLINE
0MWM
8.4MGO18" VCP
376.9FCHAIRLNE
0AMH1:55AM
398.3MGOConn. @ Mh, 9 O' Clock. Active
0MWL
398.3MGOConn. @ Mh, 3 O' Clock. OPEN
398.7AMH2:20AM

Properties (6)

custom_field_three
2 HAIRLINE FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-07-05T01:55:00-07:00
documentation
MARTIN,OLIVER 111,YOUNG
is_lateral_inspection
false