29 0113_29 0086_6292018_113447.mp4
0.1 ft. - Water Mark, 10 %of cross sectional area
2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
86.4 ft. - General Photograph
92.8 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start - 5%
98.7 ft. - General Photograph
116 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
128.4 ft. - General Photograph
128.4 ft. - General Photograph
234.3 ft. - General Photograph
236.7 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: YES, 4" - Open/50% ROOTS LATERAL
| Distance | Code | Observation |
|---|---|---|
| 276.8 | SSS | — |
| 2 | CM | — |
| 239.2 | TF | Open |
| 128.4 | MGP | — |
| 183.7 | TF | Open |
| 234.3 | MGP | — |
| 276.8 | CM | — |
| 114.5 | TFA | — |
| 79.4 | TF | Open |
| 236.7 | TFD | Open/50% ROOTS LATERAL |
| 0.1 | MWL | — |
| 30.9 | TF | Open |
| 278.5 | MGO | GREASE THROUGHOUT THE REACH (5%) |
| 92.8 | RFJ | 5% |
| 2 | SSS | — |
| 63.3 | TBA | — |
| 34.3 | TFC | — |
| 0 | AMH | 11:30 AM |
| 186.1 | TF | Open |
| 138 | TF | Open |
| 86.4 | MGP | — |
| 276.8 | RFJ | — |
| 136.1 | TF | Open |
| 128.4 | MGP | — |
| 116 | FM | — |
| 278.6 | MGO | ROACHES @ MH |
| 278.6 | AMH | 12:16 PM |
| 98.7 | MGP | — |
| 0.1 | MWM | — |
| 276.8 | FM | — |