Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2018, 07:47 AM
  • 32 0246_32 1336 _11072018_010343.mp4

Date
07/11/2018
W/O
712513
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00914
PipeID
P26307
Time
12:47 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5863
Sewer Name
32 DISTRICT #32 MAIN RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
08
Purpose
Routine Assessment
Project
WO_712513_TV32056_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
32 0246
Downstream MH
32 1336
Dir. of Survey
Downstream
Length Surveyed
381.4 ft.
Total Length
381.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2W00
O&M Rating
238
Overall Index
2
Overall Quick
Overall Rating
238
Pipe schematic from manhole 32 0246 to 32 1336
MH: 32 0246MH: 32 1336downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - STOP LOG CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 32 02460 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start78.4 ft. ISZ - Intruding Sealing Other, 5 %of cross sectional area, from 08 to 04 o'clock, Start294.3 ft. ISZ - Intruding Sealing Other, 5 %of cross sectional area, from 08 to 04 o'clock, Finish381.4 ft. AMH - Downstream Manhole, Survey Ends - 32 1336381.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish381.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Intruding Sealing Other, 5 %of cross sectional area, from 08 to 04 o'clock, Start

    78.4 ft. - Intruding Sealing Other, 5 %of cross sectional area, from 08 to 04 o'clock, Start

Observations (10)

DistanceCodeObservation
381.4AMH32 1336
78.4ISZ
381.4DAGS
0MWM
294.3ISZ
0MGOSTOP LOG CONNECTION AT MH 9 O'CLOCK
381.4MGOACTIVE CONNECTION AT MH 9 O'CLOCK
0AMH32 0246
0MWL
2DAGS

Properties (7)

additional_info
SC359730
custom_field_two
3
customer
LACSD
datetime
2018-07-11T00:47:10-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
37708