- Date
- 07/12/2018
- W/O
- 711942
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z01180
- PipeID
- P01107
- Time
- 1:00 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5773
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- SOUTH GATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_711942_TV01122_JUL2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- G 0202
- Downstream MH
- G 0201
- Dir. of Survey
- Downstream
- Length Surveyed
- 129.5 ft.
- Total Length
- 129.5 ft.
- Structural Index
- 3
- Structural Quick
- 3A22
- Structural Rating
- 34
- O&M Index
- 3
- O&M Quick
- 3C00
- O&M Rating
- 54
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 88
Pipe schematic from manhole G 0202 to G 0201 Observation photos (4)

8.4 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

21.4 ft. - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

71.8 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES, Start

76.3 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start