Section#9_G 0115_G 0114__7252018__ I0037.mp4
2 ft. - General Observation - MAG COAT 30% START
2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE START
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - TILES 20% IN PLACE 10:00 TO 2:00
24.4 ft. - General Observation - 95% MISSING TILES START
37.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - CORRODD & MISSING
56 ft. - Surface Aggregate Missing, from 12 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG--UNUSAL DEEP CORRISIN
57.3 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: NO - POSSIBLE SOIL VISIBLE
57.3 ft. - Surface Missing Wall, from 12 to 02 o'clock, within 8 inches of joint: NO - POSSIBLE SOIL VISIBLE
65.2 ft. - Surface Reinforcement Corroded, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR CORRODED & MISSING
72.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - CORRODED & MISSING
89 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
108 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
154.4 ft. - Surface Reinforcement Visible, from 10 to 11 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
189.8 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
247.7 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR BROKEN
283.3 ft. - Surface Reinforcement Corroded, from 10 to 01 o'clock, within 8 inches of joint: NO - BROKEN CIRCUM REBAR
296.1 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO, Start - CIRCUM REBAR BROKEN & MISSING
| Distance | Code | Observation |
|---|---|---|
| 302.2 | SRC | CIRCUM REBAR CORRODED & MISSING |
| 154.4 | SRV | CIRCUM REBAR |
| 247.7 | SRC | CIRCUM REBAR BROKEN |
| 302.2 | SSS | SWOLLEN & BLISTERING CONCRETE |
| 56 | SAM | SEVERE AGG--UNUSAL DEEP CORRISIN |
| 0 | AMH | 2:20AM |
| 46.9 | SRC | CURCUM REBAR CORRODED & MISSING |
| 2 | MGO | MAG COAT 30% START |
| 108 | SRV | CIRCUM REBAR |
| 57.3 | SMW | POSSIBLE SOIL VISIBLE |
| 2 | SSS | SWOLLEN BLISTERING CONCRETE START |
| 37.3 | SRC | CORRODD & MISSING |
| 2 | SAM | SEVERE AGG |
| 302.2 | MGO | MAG COAT 30% FINISH |
| 2 | MGO | TILES 20% IN PLACE 10:00 TO 2:00 |
| 89 | SRV | CIRCUM REBAR |
| 302.2 | SAM | SEVERE AGG |
| 0 | MWM | — |
| 57.3 | SMW | POSSIBLE SOIL VISIBLE |
| 296.1 | SRC | CIRCUM REBAR BROKEN & MISSING |
| 283.3 | SRC | BROKEN CIRCUM REBAR |
| 302.2 | MGO | MISSING TILES 95% FINISH |
| 65.2 | SRC | CIRCUM REBAR CORRODED & MISSING |
| 302.9 | AMH | 3:20AM |
| 72.3 | SRC | CORRODED & MISSING |
| 189.8 | SRC | CIRCUM REBAR |
| 24.4 | MGO | 95% MISSING TILES START |
| 0 | MWL | — |