Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2018, 08:53 AM
  • Section#11_G 0113_G 0086__7252018__ I0040.mp4

Date
07/25/2018
W/O
0712087
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P02174
Time
1:53 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0040
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Capital Improvement Program Assesment
Project
20180723MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
48 in.
Upstream MH
G 0113
Downstream MH
G 0086
Dir. of Survey
Downstream
Length Surveyed
322.8 ft.
Total Length
322.8 ft.
Structural Index
4
Structural Quick
5D4D
Structural Rating
273
O&M Index
5
O&M Quick
5241
O&M Rating
14
Overall Index
4
Overall Quick
Overall Rating
287
Pipe schematic from manhole G 0113 to G 0086
MH: G 0113MH: G 0086downstream0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. MWL - Water Level, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:40AM0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE2 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE2 ft. DSZ - Deposits Settled Other, 60 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - POSSIBLE MISSING TILES UNDER FLOW2 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MISSING TILES 100% START 10:00 TO 2:002 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING10.5 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR77.8 ft. MGO - General Observation - 1 ROW REMAINING TILES92.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR107 ft. MWM - Water Mark, 50 %of cross sectional area107 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR CORRODED MISSING107 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG107 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish107 ft. MWL - Water Level, 40 %of cross sectional area107 ft. MGO - General Observation - MISSING TILES 100% 9:00 TO 3:00107 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE107 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING107 ft. MGO - General Observation - TOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH107 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG110.2 ft. MGO - General Observation - 1 ROW TILES116.6 ft. MGO - General Observation - REMAINING TILES149.6 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR169.1 ft. MGO - General Observation - REMAINING TILES182.5 ft. MGO - General Observation - TILES 50% START208.6 ft. MGO - General Observation - 95% MISSING TILES START235.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR276.8 ft. MGO - General Observation - 2 ROWS TILES312.2 ft. MGO - General Observation - 2 ROWS TILES322.1 ft. MGO - General Observation - MISSING TILES 95% FINISH322.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR CORRODED MISSING322.1 ft. MGO - General Observation - MH CONN 3:00 ACTIVE LARGE INCOMING322.1 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG322.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SWOLLEN BLISTERING CONCRETE322.8 ft. AMH - Downstream Manhole, Survey Ends - 5:20AM

Observation photos (17)

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE

  • Deposits Settled Other,  60 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO - POSSIBLE MISSING TILES UNDER FLOW

    2 ft. - Deposits Settled Other, 60 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - POSSIBLE MISSING TILES UNDER FLOW

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MISSING TILES 100% START 10:00 TO 2:00

    2 ft. - General Observation - MISSING TILES 100% START 10:00 TO 2:00

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING

    2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    10.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

  • General Observation - 1 ROW REMAINING TILES

    77.8 ft. - General Observation - 1 ROW REMAINING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    92.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    107 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MISSING TILES 100% 9:00 TO 3:00

    107 ft. - General Observation - MISSING TILES 100% 9:00 TO 3:00

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING

    107 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING

  • General Observation - TOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH

    107 ft. - General Observation - TOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH

  • General Observation - REMAINING TILES

    116.6 ft. - General Observation - REMAINING TILES

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    149.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

  • General Observation - REMAINING TILES

    169.1 ft. - General Observation - REMAINING TILES

  • General Observation - TILES 50% START

    182.5 ft. - General Observation - TILES 50% START

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

    235.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR

Observations (38)

DistanceCodeObservation
107MWM
107SRCLONG CIRCUM REBAR CORRODED MISSING
2SSSSWOLLEN BLISTERING CONCRETE
0MWM
2DSZPOSSIBLE MISSING TILES UNDER FLOW
107SAMSEVERE AGG
107SSS
0MGOMH CONN 3:00 ACTIVE
10.5SRCBROKEN MISSING REBAR
107MWL
77.8MGO1 ROW REMAINING TILES
0MWL
107MGOMISSING TILES 100% 9:00 TO 3:00
322.1MGOMISSING TILES 95% FINISH
0AMH4:40AM
322.1SRCLONG CIRCUM REBAR CORRODED MISSING
208.6MGO95% MISSING TILES START
182.5MGOTILES 50% START
110.2MGO1 ROW TILES
107SSSSWOLLEN BLISTERING CONCRETE
169.1MGOREMAINING TILES
0MGOMH CONN 9:00 ACTIVE
92.7SRCCIRCUM REBAR
322.8AMH5:20AM
2SAMSEVERE AGG
116.6MGOREMAINING TILES
107SRCLONG CIRCUM REBAR CORRODED & MISSING
2MGOMISSING TILES 100% START 10:00 TO 2:00
312.2MGO2 ROWS TILES
322.1MGOMH CONN 3:00 ACTIVE LARGE INCOMING
235.2SRCBROKEN MISSING REBAR
322.1SAMSEVERE AGG
276.8MGO2 ROWS TILES
2SRCLONG & CIRCUM REBAR CORRODED & MISSING
322.1SSSSWOLLEN BLISTERING CONCRETE
107MGOTOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH
107SAMSEVERE AGG
149.6SRCBROKEN MISSING REBAR

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED & MISSING
custom_field_two
1
customer
LACSD
datetime
2018-07-25T01:53:35-07:00
documentation
MARTIN,REVELES,OLIVER 111,YOUNG
is_lateral_inspection
false