Wastewater/Activity/PacpInspection/1.0Jul 24, 2018, 01:01 PM
  • 05 1198_05 1197_7242018_062427.mp4

Date
07/24/2018
W/O
0717904
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00514
PipeID
P06438
Time
6:01 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7765
Sewer Name
05 ROSECRANS AVENUE TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
20180723DF_ROSECRANS_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
7.480000019073486 in.
Upstream MH
05 1198
Downstream MH
05 1197
Dir. of Survey
Downstream
Length Surveyed
109.6 ft.
Total Length
109.6 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 05 1198 to 05 1197
MH: 05 1198MH: 05 1197downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 6:03 AM0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. UNKNOWN0 ft. MGO - General Observation - ROACHES @ MH2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% LINER18.3 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 4"62.8 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 4" - Open/60% GREASE/LATERAL106.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish106.1 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 75% LINER109.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN109.5 ft. MGO - General Observation - Grease Throughout The Reach (5%)109.6 ft. AMH - Downstream Manhole, Survey Ends - 6:34 AM

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% LINER

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% LINER

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 4" - Open/60% GREASE/LATERAL

    62.8 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 4" - Open/60% GREASE/LATERAL

Observations (14)

DistanceCodeObservation
109.5TFUNKNOWN
0MWL
18.3TFA
2SSS
109.6AMH6:34 AM
106.1SSS
106.1SZ75% LINER
0AMH6:03 AM
0MWM
109.5MGOGrease Throughout The Reach (5%)
0MGOConn. @ Mh, 9 O' Clock. UNKNOWN
2SZ75% LINER
0MGOROACHES @ MH
62.8TFDOpen/60% GREASE/LATERAL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-07-24T06:01:45-07:00
documentation
FRANKLIN, PARAISO
is_lateral_inspection
false