- Date
- 01/13/2021
- W/O
- 864944
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00316
- PipeID
- P26646
- Time
- 9:51 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8377
- Sewer Name
- A JOA-1A DISTRICT 21 INTERCEPTOR
- City
- CITY OF INDUSTRY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 34
- Purpose
- Routine Assessment
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Width
- 54 in.
- Upstream MH
- A 0647
- Downstream MH
- A 0646
- Dir. of Survey
- Downstream
- Length Surveyed
- 911.7 ft.
- Total Length
- 911.7 ft.
- Structural Index
- 3
- Structural Quick
- 3c2c
- Structural Rating
- 905
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 905
Pipe schematic from manhole A 0647 to A 0646 Observation photos (4)

2 ft. - General Observation - 70% MAG COAT

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

113.2 ft. - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4", 4"

820.1 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 10"