Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2021, 08:02 AM
  • A 0638_A 0637_01142021_000648.mp4

Date
01/14/2021
W/O
864944
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00316
PipeID
P07843
Time
12:02 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8377
Sewer Name
A JOA-1A DISTRICT 21 INTERCEPTOR
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_864944_TV21041_DEC2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
45 in.
Width
54 in.
Upstream MH
A 0638
Downstream MH
A 0637
Dir. of Survey
Downstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
5141
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole A 0638 to A 0637
MH: A 0638MH: A 0637downstream0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 06382 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. LD - Alignment Down, 45 %2.2 ft. MSA - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observation photos (3)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

    2.2 ft. - Survey Abandoned - VIEW OF D/S SIPHON FROM U/S MH

Observations (8)

DistanceCodeObservation
2.1LD
2SAP
2DAGS
0MWM
0MWL
2.2MSAVIEW OF D/S SIPHON FROM U/S MH
2SSS
0AMHA 0638

Properties (6)

custom_field_three
AGGREGATE PROJECTING, SPALLING
custom_field_two
3
customer
1
datetime
2021-01-14T00:02:27-08:00
documentation
PRO PIPE
is_lateral_inspection
false