Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2018, 09:03 AM
  • 01 0049_01 0048A_02032018_021234.mp4

Date
03/02/2018
W/O
691313
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00714
Time
1:03 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5471
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_691313_TV01255_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0049
Downstream MH
01 0048A
Dir. of Survey
Downstream
Length Surveyed
135 ft.
Total Length
135 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
63
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
63
Pipe schematic from manhole 01 0049 to 01 0048A
MH: 01 0049MH: 01 0048Adownstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 00490 ft. MGO - General Observation - COCKROACHES IN MANHOLE24.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start54 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"56.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"102.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"106 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"131.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish135 ft. AMH - Downstream Manhole, Survey Ends - 01 0048A135 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK135 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    24.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
54TFC
135AMH01 0048A
0MWM
131.5CM
0MWL
106TFC
0AMH01 0049
24.6CM
135MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
102.2TFC
56.6TFC
135MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE

Properties (6)

additional_info
SC358477
custom_field_two
3
customer
LACSD
datetime
2018-03-02T01:03:54-08:00
documentation
PRO PIPE
is_lateral_inspection
false