Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 5, 2018, 09:26 AM
  • 01 0088_01 0087_05032018_024324.mp4

Date
03/05/2018
W/O
691313
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00757
Time
1:26 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5472
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
FLORENCE-FIRESTONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_691313_TV01255_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0087
Downstream MH
01 0088
Dir. of Survey
Upstream
Length Surveyed
310.4 ft.
Total Length
310.4 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
159
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
167
Pipe schematic from manhole 01 0087 to 01 0088
MH: 01 0087MH: 01 0088upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 00880.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish0.2 ft. MGO - General Observation - ACTIVE CONNECTION AT 9 O'CLOCK38.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"80.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"116.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"161.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"200.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"240 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"266.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start278.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"308.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start310.4 ft. MWL - Water Level, 25 %of cross sectional area310.4 ft. MWM - Water Mark, 50 %of cross sectional area310.4 ft. MGO - General Observation - ACTIVE CONNECTION AT 9 O'CLOCK310.4 ft. AMH - Downstream Manhole, Survey Begins - 01 0087

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    44.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
310.2CM
310.2DAGS
0MWL
310.4AMH01 0088
31.8TFC
229.5TF
310.2MGOACTIVE CONNECTION AT 9 O'CLOCK
0MWM
0MGOACTIVE CONNECTION AT 9 O'CLOCK
70.4TFA
109.5TFA
44.2CM
2DAGS
193.5TFA
0AMH01 0087
272.2TF
148.8TFA

Properties (6)

additional_info
SC358478
custom_field_two
3
customer
LACSD
datetime
2018-03-05T01:26:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false