Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 6, 2018, 10:57 AM
  • 01 0044_01 0043A_06032018_041325.mp4

Date
03/06/2018
W/O
691313
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00707
Time
2:57 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5473
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
WO_691313_TV01255_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0043A
Downstream MH
01 0044
Dir. of Survey
Upstream
Length Surveyed
325.6 ft.
Total Length
325.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0043A to 01 0044
MH: 01 0043AMH: 01 0044upstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOC0 ft. AMH - Upstream Manhole, Survey Ends - 01 00440.6 ft. OBZ - Obstacles Other, 0 %of cross sectional area, at 03 o'clock - D/S MH SHELF - POTENTIAL OBSTRUCTION - OR CONN. NOT NOTED ON OBSERVATION54 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"56.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 4"105.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 4"108 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"154.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"156.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"205.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"208 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"257.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"260.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"305.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"308 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"325.6 ft. AMH - Downstream Manhole, Survey Begins - 01 0043A325.6 ft. MWL - Water Level, 10 %of cross sectional area

Observations (17)

DistanceCodeObservation
117.6TFC
269.2TFC
325OBZD/S MH SHELF - POTENTIAL OBSTRUCTION - OR CONN. NOT NOTED ON OBSERVATION
120.4TFC
68.4TFC
168.8TFC
217.6TFC
0AMH01 0043A
325.6MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOC
220.1TFC
325.6AMH01 0044
0MWL
65.5TFC
20.1TFA
17.6TFC
271.6TFC
171.5TFC

Properties (6)

additional_info
SC358479
custom_field_two
4
customer
LACSD
datetime
2018-03-06T02:57:10-08:00
documentation
PRO PIPE
is_lateral_inspection
false