- Date
- 04/04/2018
- W/O
- 0699098
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00021
- PipeID
- P00606
- Time
- 1:08 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0801
- Sewer Name
- 08 VICTORIA STREET TRUNK
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180403MDM_VICTORIA_STREET_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Upstream MH
- 08 0544
- Downstream MH
- 08 0545
- Dir. of Survey
- Upstream
- Length Surveyed
- 282.8 ft.
- Total Length
- 282.8 ft.
- Structural Index
- 2
- Structural Quick
- 322A
- Structural Rating
- 30
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 30
Pipe schematic from manhole 08 0544 to 08 0545 Observation photos (3)

151.5 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: YES

187.9 ft. - General Observation - 10" VCP

282.5 ft. - General Observation - MH STACK APPERARS AS SURCHARED AT SOME TIME