Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 13, 2018, 08:51 AM
  • 05 1093_05 1092_13032018_021027.mp4

Date
03/13/2018
W/O
690188
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00488
PipeID
P06327
Time
1:51 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5482
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_690188_TV05328_MAR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
05 1093
Downstream MH
05 1092
Dir. of Survey
Downstream
Length Surveyed
322.2 ft.
Total Length
322.2 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
180
O&M Index
2
O&M Quick
412L
O&M Rating
132
Overall Index
3
Overall Quick
Overall Rating
312
Pipe schematic from manhole 05 1093 to 05 1092
MH: 05 1093MH: 05 1092downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 10932 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"17 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start103.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"206.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 4"319.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish322.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE322.2 ft. MGO - General Observation - ACTIVE CONNECTIONS AT 12 AND 9 O'CLOCK322.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1092

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
206.7TFA
322.2MGOCOCKROACHES IN MANHOLE
103.1TFA
5.6TFA
0MWM
0MWL
322.2MGOACTIVE CONNECTIONS AT 12 AND 9 O'CLOCK
321.2DAGS
0AMH05 1093
2DAGS
17CM
319.2CM
322.2AMH05 1092

Properties (6)

additional_info
SC358488
custom_field_two
3
customer
LACSD
datetime
2018-03-13T01:51:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false