- Date
- 06/25/2018
- W/O
- 712401
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00091
- PipeID
- P08875
- Time
- 10:17 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5705
- Sewer Name
- B JOINT OUTFALL B - UNIT 5A
- City
- TEMPLE CITY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_712401_TV15051_JUL2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- B 0363
- Downstream MH
- B 0362
- Dir. of Survey
- Downstream
- Length Surveyed
- 445.9 ft.
- Total Length
- 445.9 ft.
- Structural Index
- 3
- Structural Quick
- 3Q2Q
- Structural Rating
- 445
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 445
Pipe schematic from manhole B 0363 to B 0362 Observation photos (2)

2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start