Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2018, 07:41 AM
  • 32 0071_32 0070 _26062018_005752.mp4

Date
06/26/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19835
Time
12:41 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5750
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
01
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0071
Downstream MH
32 0070
Dir. of Survey
Downstream
Length Surveyed
416.7 ft.
Total Length
416.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2P00
O&M Rating
166
Overall Index
2
Overall Quick
Overall Rating
166
Pipe schematic from manhole 32 0071 to 32 0070
MH: 32 0071MH: 32 0070downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 00710 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start53 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"97.7 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"310.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"415.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish416.7 ft. AMH - Downstream Manhole, Survey Ends - 32 0070416.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
97.7TBA
0AMH32 0071
416.7AMH32 0070
53TFA
416.7MGOCOCKROACHES IN MANHOLE
415.5DAGS
310.1TBA
0MWM
0MGOCOCKROACHES IN MANHOLE
2DAGS
0MWL

Properties (7)

additional_info
SC359716
custom_field_two
4
customer
LACSD
datetime
2018-06-26T00:41:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282