Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2018, 07:29 AM
  • 32 1349_32 0071 _26062018_004100.mp4

Date
06/26/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19836
Time
12:29 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5750
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
01
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 1349
Downstream MH
32 0071
Dir. of Survey
Downstream
Length Surveyed
344 ft.
Total Length
344 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
136
Pipe schematic from manhole 32 1349 to 32 0071
MH: 32 1349MH: 32 0071downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 13490 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start51 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"103 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"201.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"285.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"342.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish344 ft. MGO - General Observation - COCKROACHES IN MANHOLE344 ft. AMH - Downstream Manhole, Survey Ends - 32 0071

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
344MGOCOCKROACHES IN MANHOLE
103TFA
285.9TBA
0AMH32 1349
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
201.1TBA
342.9DAGS
2DAGS
0MWM
344AMH32 0071
0MWL
51TBA

Properties (7)

additional_info
SC359716
custom_field_two
4
customer
LACSD
datetime
2018-06-26T00:29:20-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282