Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2018, 11:46 AM
  • 32 0007_32 0006 _09072018_045728.mp4

Date
07/09/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19771
Time
4:46 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5860
Sewer Name
32 CASTAIC TRUNK
City
VALENCIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
05
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 0007
Downstream MH
32 0006
Dir. of Survey
Downstream
Length Surveyed
322.3 ft.
Total Length
322.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 32 0007 to 32 0006
MH: 32 0007MH: 32 0006downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 00070 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start250 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"320.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish322.3 ft. AMH - Downstream Manhole, Survey Ends - 32 0006

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2DAGS
320.9DAGS
0AMH32 0007
0MWL
250TB
322.3AMH32 0006
0MWM

Properties (6)

additional_info
SC359727
custom_field_two
4
customer
LACSD
datetime
2018-07-09T04:46:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false