Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 27, 2018, 05:16 AM
  • 32 0063_32 0062 _26062018_223548.mp4

Date
06/26/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19827
Time
10:16 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5752
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
01
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0063
Downstream MH
32 0062
Dir. of Survey
Downstream
Length Surveyed
326.9 ft.
Total Length
326.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2L00
O&M Rating
128
Overall Index
2
Overall Quick
Overall Rating
131
Pipe schematic from manhole 32 0063 to 32 0062
MH: 32 0063MH: 32 0062downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 32 00630 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start295 ft. FS - Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES320.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"324.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish326.9 ft. MGO - General Observation - CAPPED CONNECTION AT MH 3 O'CLOCK326.9 ft. AMH - Downstream Manhole, Survey Ends - 32 0062

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

    295 ft. - Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
324.1DAGS
0MWL
2DAGS
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
326.9MGOCAPPED CONNECTION AT MH 3 O'CLOCK
320.5TFA
0AMH32 0063
326.9AMH32 0062
0MWM
295FS

Properties (7)

additional_info
SC359718
custom_field_two
3
customer
LACSD
datetime
2018-06-26T22:16:41-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282