Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2018, 07:05 AM
  • 32 0045_32 0044 _28062018_002313.mp4

Date
06/28/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19809
Time
12:05 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5753
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
02
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0045
Downstream MH
32 0044
Dir. of Survey
Downstream
Length Surveyed
395.7 ft.
Total Length
395.7 ft.
Structural Index
3
Structural Quick
3421
Structural Rating
14
O&M Index
2
O&M Quick
2O00
O&M Rating
158
Overall Index
2
Overall Quick
Overall Rating
172
Pipe schematic from manhole 32 0045 to 32 0044
MH: 32 0045MH: 32 0044downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 00452 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start370.6 ft. CS - Crack Spiral, from 10 to 12 o'clock, within 8 inches of joint: YES373.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start395.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish395.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish395.7 ft. AMH - Downstream Manhole, Survey Ends - 32 0044

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 10 to 12 o'clock, within 8 inches of joint: YES

    370.6 ft. - Crack Spiral, from 10 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    373.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
395.7DAGS
370.6CS
0MWM
2DAGS
373.8CM
395.7CM
395.7AMH32 0044
0MWL
0AMH32 0045

Properties (7)

additional_info
SC359719
custom_field_two
4
customer
LACSD
datetime
2018-06-28T00:05:58-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282