Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2018, 07:58 AM
  • 32 0070_32 0069 _26062018_012000.mp4

Date
06/26/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19834
Time
12:58 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5750
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
01
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0070
Downstream MH
32 0069
Dir. of Survey
Downstream
Length Surveyed
321.4 ft.
Total Length
321.4 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
2
O&M Quick
2L00
O&M Rating
128
Overall Index
2
Overall Quick
Overall Rating
129
Pipe schematic from manhole 32 0070 to 32 0069
MH: 32 0070MH: 32 0069downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 32 00700 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.7 ft. CC - Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES7.7 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"37.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"241.3 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"321.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish321.4 ft. AMH - Downstream Manhole, Survey Ends - 32 0069321.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES

    7.7 ft. - Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
37.6TBA
7.7CC
7.7TBA
241.3TBA
0MGOCOCKROACHES IN MANHOLE
321.4AMH32 0069
0AMH32 0070
321.3DAGS
2DAGS
321.4MGOCOCKROACHES IN MANHOLE
0MWL
0MWM

Properties (7)

additional_info
SC359716
custom_field_two
4
customer
LACSD
datetime
2018-06-26T00:58:29-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
27282