Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2018, 07:56 AM
  • 32 0012A_32 0012 _06072018_011320.mp4

Date
07/06/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P19777
Time
12:56 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5859
Sewer Name
32 CASTAIC TRUNK
City
CASTAIC
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
03
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
32 0012A
Downstream MH
32 0012
Dir. of Survey
Downstream
Length Surveyed
263.8 ft.
Total Length
263.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412I
O&M Rating
108
Overall Index
2
Overall Quick
Overall Rating
108
Pipe schematic from manhole 32 0012A to 32 0012
MH: 32 0012AMH: 32 0012downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 0012A0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start260.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish263.8 ft. AMH - Downstream Manhole, Survey Ends - 32 0012

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
0MWM
263.8AMH32 0012
260.7DAGS
0AMH32 0012A
0MWL
2DAGS

Properties (6)

additional_info
SC359726
custom_field_two
4
customer
LACSD
datetime
2018-07-06T00:56:03-07:00
documentation
PRO PIPE
is_lateral_inspection
false