Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 3, 2018, 11:07 AM
  • 32 0013_32 0012A _03072018_041516.mp4

Date
07/03/2018
W/O
712244
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00886
PipeID
P25493
Time
4:07 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5857
Sewer Name
32 CASTAIC TRUNK
City
VALENCIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
03
Purpose
Routine Assessment
Project
WO_712244_TV32012_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
32 0013
Downstream MH
32 0012A
Dir. of Survey
Downstream
Length Surveyed
89.5 ft.
Total Length
89.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
512B
O&M Rating
39
Overall Index
2
Overall Quick
Overall Rating
39
Pipe schematic from manhole 32 0013 to 32 0012A
MH: 32 0013MH: 32 0012Adownstream0 ft. MWM - Water Mark, 75 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 00132 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start87.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish89.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK89.5 ft. AMH - Downstream Manhole, Survey Ends - 32 0012A

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWM
2DAGS
89.5MGOACTIVE CONNECTION AT MH 3 O'CLOCK
89.5AMH32 0012A
87.7DAGS
0MWL
0AMH32 0013

Properties (6)

additional_info
SC359724
custom_field_two
4
customer
LACSD
datetime
2018-07-03T04:07:26-07:00
documentation
PRO PIPE
is_lateral_inspection
false