Section#5_G 0117_G 0116__7202018__I0035.mp4
2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING
2 ft. - General Observation - MISSING TILES 50% 10:00 TO 2:00 START
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
10.9 ft. - General Observation - CORRISON BEYOUND REBAR
10.9 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR MISSING
13.6 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CORRODED & MISSING
19.8 ft. - General Observation - TILES IN PLACE 90% START
50.3 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR CORRODED & MISSING
83.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR MISSING & CORRODED
99.7 ft. - General Observation - 195% MISSING TILES START
124.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM
132.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING AREAS OF MISSING TILES
181.1 ft. - General Observation - 100% MISSING TILES
195.1 ft. - General Observation - 100% MISSING TILES
227.5 ft. - General Observation - 100% MISSING TILES
238.5 ft. - General Observation - 100% MISSING TILES
247.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG & CIRCUM REBAR
257.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CORRODED MISSING REBAR LONG & CIRCUM
474.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
| Distance | Code | Observation |
|---|---|---|
| 2 | MGO | TILES 100% IN PLACE UNDER MAG COAT |
| 132.9 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING AREAS OF MISSING TILES |
| 521.4 | SRC | LONG & CIRCUM REBAR |
| 521.8 | AMH | 3:00AM |
| 305 | MGO | MISSING TILES 70% START |
| 247.9 | SRC | LONG & CIRCUM REBAR |
| 83.6 | SRC | LONG & CIRCUM REBAR MISSING & CORRODED |
| 521.4 | SRC | CORRODED & MISSING LONG & CIRCUM REBAR |
| 195.1 | MGO | 100% MISSING TILES |
| 227.5 | MGO | 100% MISSING TILES |
| 181.1 | MGO | 100% MISSING TILES |
| 0 | MWM | — |
| 0 | MGO | MAG COAT 100% START 8:00 TO 4:00 |
| 474.1 | SRC | BROKEN MISSING REBAR |
| 124.9 | SRC | LONG & CIRCUM |
| 521.4 | MGO | MH CONN 9:00 ACTIVE |
| 13.6 | SRC | CORRODED & MISSING |
| 10.9 | MGO | CORRISON BEYOUND REBAR |
| 124.9 | MGO | 50% MISSING TILES START |
| 50.3 | SRC | CIRCUM REBAR CORRODED & MISSING |
| 19.8 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING |
| 97 | SRC | CORRODED & MISSING REBAR |
| 521.4 | SAM | SEVERE AGG |
| 19.8 | SAM | SEVERE AGG AREAS OF MISSING TILES |
| 99.7 | MGO | 195% MISSING TILES START |
| 2 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING |
| 238.5 | MGO | 100% MISSING TILES |
| 0 | MWL | — |
| 124.9 | SRC | LONG & CIRCUM |
| 2 | MGO | MISSING TILES 50% 10:00 TO 2:00 START |
| 2 | SAM | SEVERE AGG |
| 121.5 | MGO | MISSING TILES 70% FINISH |
| 19.8 | MGO | TILES IN PLACE 90% START |
| 19.8 | MGO | MAG COAT 40% START 10:00 TO 2:00 |
| 10.9 | SRC | LONG & CIRCUM REBAR MISSING |
| 0 | AMH | 1:50AM |
| 19.8 | SAM | SEVERE AGG |
| 257.5 | SRC | CORRODED MISSING REBAR LONG & CIRCUM |