C 0332_C 0331A_7172018_042734.mp4
9.9 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT
76.2 ft. - Surface Spalling, from 09 to 10 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
84.7 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
89.6 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG
275.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
342.7 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG
368.7 ft. - Surface Spalling, from 01 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
408.8 ft. - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 408.8 | SAV | SEVERE AGG |
| 84.7 | SAV | SEVERE AGG |
| 0 | AMH | 4:30AM |
| 460.3 | SAV | SEVERE AGG SPORATIC |
| 460.8 | AMH | 5:05AM |
| 9.9 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 0 | MWM | — |
| 76.2 | SSS | BLISTERING CONCRETE |
| 460.3 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 368.7 | SSS | BLISTERING CONCRETE |
| 342.7 | SAV | SEVERE AGG |
| 89.6 | SAV | SEVERE AGG |
| 275.8 | SAV | SEVERE AGG SPORATIC |
| 0 | MWL | — |