- Date
- 07/13/2018
- W/O
- 0716531
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00138
- PipeID
- P09803
- Time
- 1:25 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0933
- Sewer Name
- C JOINT OUTFALL C - UNIT 7B
- City
- HAWAIIAN GARDENS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 08
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180713MDM_JOINT_OUTFALL_C_UNIT_7B
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- C 0339
- Downstream MH
- C 0340
- Dir. of Survey
- Upstream
- Length Surveyed
- 92.7 ft.
- Total Length
- 92.7 ft.
- Structural Index
- 2
- Structural Quick
- 2100
- Structural Rating
- 2
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 2
Pipe schematic from manhole C 0339 to C 0340 Observation photos (3)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT

2 ft. - General Observation - MAG COAT80% START 9:00 TO 3:00

39.9 ft. - General Observation - MAG COAT 98% START