Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 5, 2018, 06:05 AM
  • 18 0488_18 1194 _04012018_220618.mp4

Date
01/04/2018
W/O
679859
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00687
PipeID
P15040
Time
10:05 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5303
Sewer Name
18 LOWER SPRINGS ROAD TRUNK REPLACEMENT
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
WO_679859_TV18109_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1194
Downstream MH
18 0488
Dir. of Survey
Upstream
Length Surveyed
94.8 ft.
Total Length
94.8 ft.
Structural Index
3
Structural Quick
3C00
Structural Rating
54
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
54
Pipe schematic from manhole 18 1194 to 18 0488
MH: 18 1194MH: 18 0488upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 04880.1 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish91.8 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start94.8 ft. AMH - Downstream Manhole, Survey Begins - 18 1194, VERMIN94.8 ft. MWM - Water Mark, 10 %of cross sectional area94.8 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (1)

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0AMH18 1194, VERMIN
0MWM
94.7CM
3CM
0MWL
94.8AMH18 0488

Properties (7)

additional_info
SC346777
custom_field_two
3
customer
LACSD
datetime
2018-01-04T22:05:48-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
31671