Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 27, 2017, 08:05 AM
  • 01 0353_01 0352_12272017_000630.mp4

Date
12/27/2017
W/O
679333
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00215
PipeID
P00827
Time
12:05 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5294
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
06
Purpose
Routine Assessment
Project
WO_679333_TV01077_JAN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0353
Downstream MH
01 0352
Dir. of Survey
Downstream
Length Surveyed
432.6 ft.
Total Length
432.6 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
129
O&M Index
2
O&M Quick
2P00
O&M Rating
172
Overall Index
2
Overall Quick
Overall Rating
301
Pipe schematic from manhole 01 0353 to 01 0352
MH: 01 0353MH: 01 0352downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 01 03530 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start233 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start425 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish430.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish432.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0352432.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    233 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MGOCOCKROACHES IN MANHOLE
0AMH01 0353
0MWM
2DAGS
0MWL
425CM
432.6AMH01 0352
430.5DAGS
432.6MGOCOCKROACHES IN MANHOLE
233CM

Properties (6)

additional_info
SC346431
custom_field_two
3
customer
LACSD
datetime
2017-12-27T00:05:45-08:00
documentation
PRO PIPE
is_lateral_inspection
false