Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 20, 2018, 08:55 AM
  • Section#5_H 0105_H 0104__1202018__G6927.mp4

Date
01/20/2018
W/O
0693963
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00165
PipeID
P10557
Time
12:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6927
Sewer Name
H JOINT OUTFALL H - UNIT 1F
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20180119MDM_JOINT_OUTFALL_H_UNIT_1F
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
H 0105
Downstream MH
H 0104
Dir. of Survey
Downstream
Length Surveyed
590.9 ft.
Total Length
590.9 ft.
Structural Index
2
Structural Quick
2W00
Structural Rating
240
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
240
Pipe schematic from manhole H 0105 to H 0104
MH: H 0105MH: H 0104downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM2 ft. MGO - General Observation - THICK MAG COAT2 ft. MGO - General Observation - MAG COAT 90% START 8:00 TO 4:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE33.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE37.1 ft. MGO - General Observation - 80% MAG COAT START120 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT590.5 ft. MGO - General Observation - 80% MAG COAT FINISH590.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE590.9 ft. AMH - Downstream Manhole, Survey Ends - 2:05

Observation photos (5)

  • General Observation - THICK MAG COAT

    2 ft. - General Observation - THICK MAG COAT

  • General Observation - MAG COAT 90% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 90% START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    33.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

    120 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT

Observations (12)

DistanceCodeObservation
2MGOTHICK MAG COAT
590.9AMH2:05
37.1MGO80% MAG COAT START
33.5SSSBLISTERING PEELING CONCRETE
0MWL
590.5MGO80% MAG COAT FINISH
590.5SSSBLISTERING PEELING CONCRETE
2MGOMAG COAT 90% START 8:00 TO 4:00
120SSSBLISTERING CONCRETE UNDER MAG COAT
2SSSBLISTERING PEELING CONCRETE
0MWM
0AMH1:15AM

Properties (6)

custom_field_three
80% MAG COAT
custom_field_two
3
customer
LACSD
datetime
2018-01-20T00:55:08-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false