- Date
- 01/20/2018
- W/O
- 0693963
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00165
- PipeID
- P10557
- Time
- 12:55 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6927
- Sewer Name
- H JOINT OUTFALL H - UNIT 1F
- City
- HUNTINGTON PARK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20180119MDM_JOINT_OUTFALL_H_UNIT_1F
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- H 0105
- Downstream MH
- H 0104
- Dir. of Survey
- Downstream
- Length Surveyed
- 590.9 ft.
- Total Length
- 590.9 ft.
- Structural Index
- 2
- Structural Quick
- 2W00
- Structural Rating
- 240
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 240
Pipe schematic from manhole H 0105 to H 0104 Observation photos (5)

2 ft. - General Observation - THICK MAG COAT

2 ft. - General Observation - MAG COAT 90% START 8:00 TO 4:00

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

33.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

120 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE UNDER MAG COAT