Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2018, 07:38 PM
  • Section#2_J 0392_J 0391__1182018__G6925.mp4

Date
01/18/2018
W/O
0684703
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00064
PipeID
P21082
Time
11:38 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6925
Sewer Name
J JOINT OUTFALL J - UNIT 2E
City
TORRANCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
28
Purpose
Routine Assessment
Project
20180118DF_JOINT_OUTFALL_J_UNIT_2E
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Upstream MH
J 0392
Downstream MH
J 0391
Dir. of Survey
Downstream
Length Surveyed
261.8 ft.
Total Length
261.8 ft.
Structural Index
2
Structural Quick
2I00
Structural Rating
104
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
106
Pipe schematic from manhole J 0392 to J 0391
MH: J 0392MH: J 0391downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:39 AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start89 ft. MGP - General Photograph159.3 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 10 to 04 o'clock, , within 8 inches of joint: YES165.7 ft. MGP - General Photograph211.8 ft. MGP - General Photograph252.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES258 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish261.6 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH (5%)261.8 ft. AMH - Downstream Manhole, Survey Ends - 11:51 AM

Observation photos (6)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    89 ft. - General Photograph

  • Deposits Settled Compacted,  5 %of cross sectional area, from 10 to 04 o'clock,  , within 8 inches of joint: YES

    159.3 ft. - Deposits Settled Compacted, 5 %of cross sectional area, from 10 to 04 o'clock, , within 8 inches of joint: YES

  • General Photograph

    165.7 ft. - General Photograph

  • General Photograph

    211.8 ft. - General Photograph

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    252.5 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (12)

DistanceCodeObservation
0MWL
89MGP
0MWM
261.6MGOSLIGHT GREASE THROUGHOUT THE REACH (5%)
258SSS
159.3DSC
2SSS
211.8MGP
252.5CL
0AMH11:39 AM
165.7MGP
261.8AMH11:51 AM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-01-18T11:38:19-08:00
documentation
FRANKLIN, IGNACIO, VENDRYES, PARAISO
is_lateral_inspection
false