Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 29, 2018, 06:39 PM
  • Section#8_A 0313_A 0312__5292018__I0017.mp4

Date
05/29/2018
W/O
0706684
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00325
PipeID
P08223
Time
11:39 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0017
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20180525DF_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
A 0313
Downstream MH
A 0312
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
5131
Structural Rating
10
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole A 0313 to A 0312
MH: A 0313MH: A 0312downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:05 PM0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MWL - Water Level, 100 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 65% MAG2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MGO - General Observation - AIRLINE2.1 ft. MSA - Survey Abandoned - 12:20 PM

Observation photos (7)

  • Water Mark, 100 %of cross sectional area

    0 ft. - Water Mark, 100 %of cross sectional area

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 65% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES - 65% MAG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - AIRLINE

    2 ft. - General Observation - AIRLINE

  • Survey Abandoned - 12:20 PM

    2.1 ft. - Survey Abandoned - 12:20 PM

Observations (9)

DistanceCodeObservation
2SAV
0AMH12:05 PM
2SRV
2SZ65% MAG
0MWM
2.1MSA12:20 PM
2SSS
0MWL
2MGOAIRLINE

Properties (6)

additional_info
VIEW OF THE DOWNLEG FROM THE U/S SIPHON
custom_field_two
5
customer
LACSD
datetime
2018-05-29T11:39:45-07:00
documentation
FRANKLIN, SHADLER, PARAISO
is_lateral_inspection
false