Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 6, 2018, 09:58 AM
  • 18 0625_18 0624 _06062018_031518.mp4

Date
06/06/2018
W/O
707102
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00692
PipeID
P14475
Time
2:58 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5639
Sewer Name
18 NORTH PLANT OUTFALL RELIEF TRUNK
City
WHITTIER, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_707102_TV18034_JUN2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
18 0624
Downstream MH
18 0625
Dir. of Survey
Upstream
Length Surveyed
339 ft.
Total Length
339 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 18 0624 to 18 0625
MH: 18 0624MH: 18 0625upstream0 ft. MLC - Lining Change, Cured in place - FINISH0 ft. AMH - Upstream Manhole, Survey Ends - 18 062511 ft. LR - Alignment Right, 10 %, Finish57 ft. LR - Alignment Right, 10 %, Start339 ft. AMH - Downstream Manhole, Survey Begins - 18 0624339 ft. MWL - Water Level, 20 %of cross sectional area339 ft. MLC - Lining Change, Cured in place - START339 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (2)

  • Lining Change, Cured in place - START

    0 ft. - Lining Change, Cured in place - START

  • Alignment Right, 10 %, Start

    282 ft. - Alignment Right, 10 %, Start

Observations (8)

DistanceCodeObservation
339MLCFINISH
339AMH18 0625
0AMH18 0624
0MWL
0MLCSTART
0MWM
282LR
328LR

Properties (8)

additional_info
SC359194
custom_field_two
4
customer
LACSD
datetime
2018-06-06T02:58:17-07:00
documentation
PRO-PIPE
is_lateral_inspection
false
lining
CIPP
year_laid
36052