Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 21, 2018, 10:22 AM
  • 08 0680_08 0138 _21062018_032935.mp4

Date
06/21/2018
W/O
707209
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00006
PipeID
P00195
Time
3:22 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5741
Sewer Name
08 FIGUEROA STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_707209_TV08173_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
08 0680
Downstream MH
08 0138
Dir. of Survey
Downstream
Length Surveyed
78.9 ft.
Total Length
78.9 ft.
Structural Index
3
Structural Quick
413B
Structural Rating
52
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
52
Pipe schematic from manhole 08 0680 to 08 0138
MH: 08 0680MH: 08 0138downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 06800 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.7 ft. FM - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES30.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"40.7 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES76.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish76.9 ft. MMC - Material Change, Vitrified clay pipe78.9 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK78.9 ft. AMH - Downstream Manhole, Survey Ends - 08 0138

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    26.7 ft. - Fracture Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    40.7 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Material Change, Vitrified clay pipe

    76.9 ft. - Material Change, Vitrified clay pipe

Observations (12)

DistanceCodeObservation
26.7FM
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
2SAP
78.9MGOACTIVE CONNECTION AT MH 9 O'CLOCK
76.9SAP
78.9AMH08 0138
0MWL
30.3TFC
40.7CM
0AMH08 0680
0MWM
76.9MMC

Properties (6)

additional_info
SC359707
custom_field_two
3
customer
LACSD
datetime
2018-06-21T03:22:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false