Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2018, 04:52 AM
  • 08 0142_08 0141A _21062018_221318.mp4

Date
06/21/2018
W/O
707209
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00006
PipeID
P25249
Time
9:52 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5742
Sewer Name
08 FIGUEROA STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
WO_707209_TV08173_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
08 0142
Downstream MH
08 0141A
Dir. of Survey
Downstream
Length Surveyed
123.3 ft.
Total Length
123.3 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
75
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
75
Pipe schematic from manhole 08 0142 to 08 0141A
MH: 08 0142MH: 08 0141Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 01420 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"76.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"114.9 ft. CM - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES121 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish123.3 ft. AMH - Downstream Manhole, Survey Ends - 08 0141A123.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

    114.9 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
123.3AMH08 0141A
13.1TBA
0AMH08 0142
76.1TFC
121SAP
0MWM
0MWL
2SAP
114.9CM
123.3MGOACTIVE CONNECTION AT MH 9 O'CLOCK

Properties (6)

additional_info
SC359708
custom_field_two
2
customer
LACSD
datetime
2018-06-21T21:52:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false