Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 11, 2018, 11:01 AM
  • 18 0650_18 0005 _11062018_040736.mp4

Date
06/11/2018
W/O
706968
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00713
PipeID
P13821
Time
4:01 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5190
Sewer Name
18 WALNUT WAY TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_706968_TV18059_JUN2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0650
Downstream MH
18 0005
Dir. of Survey
Downstream
Length Surveyed
49.6 ft.
Total Length
49.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 0650 to 18 0005
MH: 18 0650MH: 18 0005downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - LINER0 ft. AMH - Upstream Manhole, Survey Begins - 18 06500 ft. MWM - Water Mark, 25 %of cross sectional area5.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start48.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish49.6 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH49.6 ft. AMH - Downstream Manhole, Survey Ends - 18 0005

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    5.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
49.6MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
0MWL
5.4DAE
49.6AMH18 0005
48.1DAE
0MGOLINER
0AMH18 0650
0MWM

Properties (7)

additional_info
SC359513
custom_field_two
5
customer
LACSD
datetime
2018-06-11T04:01:58-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP