Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 19, 2018, 09:18 AM
  • 15 0105_15 0104 _19062018_023014.mp4

Date
06/19/2018
W/O
706913
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00590
PipeID
P11983
Time
2:18 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5734
Sewer Name
15 ABBEY STREET TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
WO_706913_TV15007_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0105
Downstream MH
15 0104
Dir. of Survey
Downstream
Length Surveyed
35.3 ft.
Total Length
35.3 ft.
Structural Index
3
Structural Quick
3600
Structural Rating
18
O&M Index
2
O&M Quick
2600
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 15 0105 to 15 0104
MH: 15 0105MH: 15 0104downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 01040 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start32.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish32.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish35.3 ft. AMH - Downstream Manhole, Survey Ends - 15 010435.3 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 12 O'CLOCK

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
35.3AMH15 0104
2CM
0AMH15 0104
2DAGS
0MWL
32.8CM
35.3MGOACTIVE CONNECTION AT MH 12 O'CLOCK
32.8DAGS
0MWM

Properties (6)

additional_info
SC359400
custom_field_two
3
customer
LACSD
datetime
2018-06-19T02:18:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false