Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 4, 2018, 10:54 AM
  • 02 1388_02 1387 _04062018_041818.mp4

Date
06/04/2018
W/O
706877
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00242
PipeID
P03906
Time
3:54 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5184
Sewer Name
02 CLOVERLAWN TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_706877_TV02041_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1388
Downstream MH
02 1387
Dir. of Survey
Downstream
Length Surveyed
351.5 ft.
Total Length
351.5 ft.
Structural Index
3
Structural Quick
4135
Structural Rating
21
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
23
Pipe schematic from manhole 02 1388 to 02 1387
MH: 02 1388MH: 02 1387downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13880 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. FM - Fracture Multiple, from 06 to 11 o'clock, within 8 inches of joint: YES12.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start41.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES135 ft. CM - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES135.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"142.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"168.1 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES178.5 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES185.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start193.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"243.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"338.6 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area344.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"349.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish349.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish351.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1387

Observation photos (7)

  • Fracture Multiple, from 06 to 11 o'clock, within 8 inches of joint: YES

    2 ft. - Fracture Multiple, from 06 to 11 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    12.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    117.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES

    135 ft. - Crack Multiple, from 02 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

    168.1 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    178.5 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    185.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
117.7CM
135CM
0AMH02 1388
294.3TFC
2FM
344.7TFC
349.2DAGS
135.7TB
193.1TFC
142.8TFC
338.6MWLS
185.3CM
168.1CM
178.5CM
92.7TFC
243.7TFC
349.2CM
41.5TFC
0MWL
12.4DAGS
0MWM
351.5AMH02 1387

Properties (6)

additional_info
SC359506
custom_field_two
3
customer
LACSD
datetime
2018-06-04T03:54:14-07:00
documentation
PROPIPE
is_lateral_inspection
false